Year : 1992  |  Volume : 10  |  Issue : 1  |  Page : 32-34

Evaluation Of Rhelax ASO Slide Test For Antistreptolysin '0'



Correspondence Address:
A.K Kapoor


Login to access the Email id

Source of Support: None, Conflict of Interest: None


Rights and PermissionsRights and Permissions

In present study 120 serum samples obtained from sore throat, rheumatic fever & rheumatic heart disease were screened with Rhelax ASO slide test for antistreptolysin ‘O’ and by conventional method. It was observed that results were same in 93.3%, 4.0% sera gave false positive tests and 2.5% sera showed false negative tests, with Rhelax ASO slide test.